Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

Product Description

Benchtop Conductivity Meter LBCM-A14 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With setup menu, it does setting of 6 parameters calibration points, temperature units and others. Large LCD display shows settings and measurement values. Temperature calibration by manual method improves the accuracy of conductivity meter.catalog/Benchtop-Conductivity-Meter-LBCM-A14.pdf

    Share:

Available Range :

Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm Conductivity measurement range : 0.000 μS/cm to 3000mS/cm Conductivity Mode : Conductivity measurement range : 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm TDS Mode : TDS measurement Range : 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) Temperature Mode : Temperature range : 0 to 105°C, 32 to 221°F Cell constant : K=0.1, 1, 10
Conductivity Mode
Conductivity measurement range0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity accuracy±1% F.S.
Conductivity resolution0.001, 0.01, 0.1, 1
Conductivity calibration points1 to 3 points
Conductivity calibration solutions10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
TDS Mode
TDS measurement Range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy± 1 % F.S.
TDS Factor0.01 to 1.00 (default 0.5)
TDS Calibration points3 points
Temperature Mode
Temperature range0 to 105°C, 32 to 221°F
Temperature accuracy±1°C
Temperature resolution0.1°C, 0.1°F
Temperature calibration points1 point
Temperature Compensation Range and ModeManual or Automatic, 0 to 100°C , 32 to 212°F
Temperature coefficient0.0 to 10.0 % per °C
Cell constant K=0.1, 1, 10
Power requirements DC 9 V, using AC adapter, AC 220 V, 50 Hz
Dimension (L×W×H) 210 × 205 × 75 mm
Weight 1.5 kg

  • Measures conductivity, TDS, Temperature of the liquids
  • Automatic temperature compensation for accurate values over the entire range
  • Selectable temperature units (°C or °F) for different application requirements
  • Reset function automatically resumes all the setting back to factory default options
  • Manual and automatic mode of temperature calibration
  • Auto hold feature to lock, record and read stable measurement endpoint
  • Stability indicator displays the status of current measurement
  • Help message as an operational guide, with quick access to test parameters
  • Conductivity/TDS Mode
  • 1 to 3 Conductivity push button calibration points
  • 3 TDS calibration points
  • 1 Temperature calibration point

Used to test Conductivity, TDS values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose

Accessories no. Name
1 Conductivity Electrode (range 0.01 to 20 mS/ cm)
2 Temperature Probe
3 Conductivity Calibration Standard Solutions
4 Electrode Holder
5 Power Adapter

Accessories no. Name
1 Conductivity Electrode (K=0.1) suitable for measuring the low conductivity liquids ( <10µS/ cm) e.g. Pure water
2 Conductivity Electrode (K=10) suitable for measuring the high conductivity liquids (>20mS/ cm) e.g. Sea water