Table top spectrophotometer LTS-A12

Table top spectrophotometer LTS-A12

Product Description

Table top spectrophotometer LTS-A12 has multiple measuring calibers with largest caliber of 25.4 mm, satisfies the measurement needs of samples of different size. It is possible to measure the color data of opaque samples and transmission and opacity of transparent or semi-transparent samples. Equipped with dual light path spectral analysis technology ensures precision and long-term stability of the instrument. The 8°/diffused illumination geometric design of lightning, provides full insight of the color data.catalog/Tabletop-spectrophotometer.pdf

    Share:

Available Range :

Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Wavelength Range : 360 nm to 780 nm Illumination system : d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement Wavelength Range : 400 nm to 700 nm Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Illumination system d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 15.2 cm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array
Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength range 400-700 nm
Wavelength interval 10 nm
Half spectral width 5 nm
Reflectivity range & resolution 0 to 200%, 0.01%
Measurement caliber LAV: large aperture: 2.54 cm (1 inch)
MAV: middle aperture: 1.5 cm (0.6 inch)
SAV: small aperture: 0.75cm× 1.0 cm (0.3 inch×0.4 inch)
VSAV: very small aperture: 0.3 cm× 0.8 cm (0.12 inch× 0.31 inch)
Measurement time interval 2 s
Measurement time 2 s
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK
Color difference formula ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 color classification
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby)
YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density
Repeatability light splitting reflectivity:standard deviation within 0.08%
color values:ΔE*ab<=0.015 (
After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03
Work temperature range 0 to 45°C, relative humidity 80% or below (at 35°C), no condensation
Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
Data being displayed Samples color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, display measurement area,history data color simulation,manual input standard sample generate measurement report
Interface USB
Display 5 inch TFT touch screen
Data storage 20000 test results
Light source longevity 10 years, 3 million tests
Dimension (L*W*H) 583 × 330 × 304 mm
Weight 18 kg

  • Dual light path spectral analysis technology
  • Manual fitting of white calibration board on measurement port
  • Four measurement calibers, maximum is 25.4 mm
  • Large display screen for easier measurement and settings
  • Flexible measurement fixtures
  • Simultaneously measures SCI and SCE
  • PC connection for data transmission, software, storage
  • Reflection and transmission measurement
  • Adjustable UV components (light source) percentage value

Table top spectrophotometer with multiple measuring calibers has applications in measurement of solid as well as liquid material at multiple calibration points.

Accessories No. Name
1 Power cord
2 USB cable
3 Driving software
4 Color QC software
5 Black and white calibration tile