Generate Catalog For :

Gas Chromatography LGC-B11

Laboratorybiz

Personalized PDF Catalog

Catalog Generated On : 11/09/2025


Gas Chromatography LGC-B11

Gas Chromatography LGC-B11

Description :

Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors.


Specifications:

Oven
Maximum capacityTemperature rangeTemperature accuracyTemperature programProgram total timeMaximum temperature heating rateMaximum cooling rate
22 LRT + 5 ℃ to 400 ℃± 0.1 ℃9-phase/ 10 platform9999.9 min0.1 to 60 ℃/ min˂ 10 mins (250 to 50 ℃)
Sample injector
Temperature rangeTemperature controlInjector typeMaximum sample inletCarrier gas flow typePre column pressure rangePre column pressure accuracyMobile phase flow range
RT+ 7 ℃ to 420 ℃AutomaticColumn or split3 pcsConstant pressure0 to 400 kPa0.1 kPaH2: 0 to 200 ml/min, N2: 0 to 150 ml/min
Detector
Temperature rangeMaximum installationFlame ignition modeFlame Ionization Detector (FID)
RT + 7 ℃ to 420 ℃Dual detectorAutomaticLogarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10 -13 A
Dynamic range: 10 7
RSD: ≤ 3 %
Power supply AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W
Packing dimension 1020 × 660 × 740 mm
Gross Weight 82 kg
Net weight 70 kg

Features:

    • 7-inch LCD display specifies temperature, gas flow and heating curve
    • H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
    • Equipped with capillary analysis system and capillary split sampler
    • Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
    • Standard unit for high-speed analysis with polar capillary column
    • PEG-20M and FFAP stationary phase polar capillary columns can be coupled
    • Dual FID detector with automatic flame ignition and baseline signal display
    • Self-diagnostic and automatic fault recognition function
    • Multi-core and 32-bit embedded hardware system ensures the reliable operation
    • Equipped with chromatography workstation software to process data
    • Memory function can store 20 sample test data
    • RS232 interface and LAN port

Applications:

Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.


Standard Accessories:

Accessories no Accessories name
1.        FID detector system
2.        Capillary injection system
3.        Chromatography workstation software


Optional Accessories:

Accessories no Accessories name
1 Polar capillary columns PEG-20M
Stationary phase: 30 m × 0.32 mm
injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
2 Polar capillary columns FFAP
Stationary phase: 30 m × 0.32 mm
Injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
3 Syringe 1 ul
4 Syringe 5 ul


Laboratorybiz

Laboratorybiz

Email: info@laboratorybiz.com | Website: www.laboratorybiz.com | Phone: +442080043608